Search results
626
Accessory
FPT Tear Vice-Grips (pair), 100 mm rubber jaws, QC-8
432-625
A Lightweight Double-action Vice Grip providing free adjustment of both jaws, allowing them to be aligned around the central axis to accommodate tensile and tear testing of both symmetrical and asymmetrical specimens.
Fitted with 100mm-wide, rubber-…
627
Accessory
V-jaw vice clamp, four jaws on screw-action adjuster, QC-20 fitting
432-678
432-678 is a vice fixture for mounting to the base of a test stand when performing tension and compression tests. It has four jaws, with two jaws being vertically spaced on either side. This provides increased stability by clamping at alternate heights on…
628
Accessory
U-Form Pneumatic Vice Grip - Double Action, 2.5 kN, 18 mm opening, pair, QC-20 fitting
Mec240g+2Ko
MEC 240g +2kO (body only) :
A pair of pneumatically-operated, Double-action U-form Vice Grips with an opening of 0-18mm depending on the jaw types selected (sold separately).
Each grip is fitted with 2 x 70 mm diameter pneumatic pistons, which allow…
629
Accessory
Wire Grip, 500 N, 10-32 UNF
432-397
The Wire Grip is designed for tensile testing up to 500 N of flexible thin wires, which may break easily when clamped.
The specimen is wrapped around a grooved 19 mm diameter bollard and the free end is clamped tightly in place using a pair of friction…
630
Accessory
Pneumatic Medium Vice Grip - Double Action, 1 kN, 20 mm opening, pair, QC-20 fitting
Mec240k-S20+2Ko
MEC 240k- S20+2kO (body only) :
A pair of pneumatically-operated, Double-action Medium Vice Grips with an opening of 0-20mm depending on the jaw types selected. Each grip is fitted with 2 x 50 mm diameter pneumatic pistons, which allow the test specimen…
631
Accessory
Mini V-block, for Orbis & Tornado
432-423
The Mini V-block is a precision-engineered vice assembly which allows smaller specimens to be securely held in a centrally-aligned position, without excessive clamping force.
Supplied with V-shape, rubber-coated, interlocking jaws with an opening span…
632
Accessory
Eccentric Roller Grip - Pyramid (serrated) roller, 5 kN, QC-20 fitting
Mec7-5
MEC7-5
Eccentric Cam Grip fitted with a pyramid-faced serrated 50mm wide roller cam. As a load is applied to a specimen the cam self-tightens , spreading the load evenly.
The lever allows for quick insertion and release of specimen to reduce testing…
633
Accessory
Multi-Jaw Grip, 500 N, M6
432-215
Used in tension tests the Multi-Jaw Grip is for holding round and irregularly shaped specimens by clamping on the outer surface or under a 'head'.
By turning the body of the grip the claw-type jaws can be opened and closed to get a secure grasp on a…
634
Accessory
Parallel Jaw Grip, 500 N, 10-32 UNF
432-396
Parallel Jaw Grips are designed for tensile testing up to 500N of thin flat components and materials, which require secure gripping over an extended surface area.
Star handles allow jaw positions to be adjusted to ensure central loading during tensile…
635
Accessory
Medium Vice Grip - Single Action, 2 kN, 20 mm opening, QC-20 fitting
Mec240k-S20
MEC 240k-S20 (body only) :
A Medium Single-action Vice Grip allowing one jaw to be manually set in a position to align a test specimen around the central axis. The other jaw is freely adjustable to mechanically clamp the specimen in place.
Rated to 2…
636
Accessory
Multi-Jaw Grip, 500 N, 10-32 UNF
432-420
Used in tension tests the Multi-Jaw Grip is for holding round and irregularly shaped specimens by clamping on the outer surface or under a 'head'.
By turning the body of the grip the claw-type jaws can be opened and closed to get a secure grasp on a…
637
Accessory
Pneumatic Medium Vice Grip - Single Action, 1 kN, 52 mm opening, pair, QC-20 fitting
Mec240k-S50+Ko
MEC 240k- S50+kO (body only) :
A pair of pneumatically-operated, single-action Medium Vice Grips with an opening of 0-52mm depending on the jaw types selected (sold separately). Each grip is fitted with 1 manual jaw holder + 1 x 50 mm diameter pneumatic…
638
Accessory
Crosshead Extension and Elevated Base Plate
432-406
The 38mm crosshead extension and elevated base plate are supplied together. They are used for fitting larger samples up to 200 mm diameter, to a single-column MultiTest system. When fitted, the cantilever effect of such an extension serves to reduce the…
639
Accessory
Clevis Grip (Large) c/w quick-release pin, 5 kN, M12
432-443
Large Clevis Grip c/w quick-release pin.Fitted with female M12 thread.
Used for testing heavy duty tension springs and securing odd-shaped parts when testing tensile forces below 5 kN.
640
Test Frame
OmniTest测试框架(双列)
OmniTest测试框架一种由双滚珠丝杠驱动的电动测试架,该双滚珠丝杠具有双柱,旨在施加从2 N到50 kN (1100 lbf)的拉力和压力。 其多功能的结构使其非常适合在质量控制或研发环境中测试各种材料。 查看测试框架
641
Case study
肩关节假体拉伸测试
要求布莱顿大学医学院著名骨科外科医生Keith Borowsky先生正在开发一种用于肩关节重建的新型骨科假体。肩假体用于代替老年人跌倒时骨折的肩膀,偶尔还可以在高能量的汽车碰撞或直接暴力创伤后进行。它们也可用于需要肩关节置换的其他情况,例如关节炎患者。假体需要进行测试,以确保它们正确地附着在周围的骨骼和肌腱上,从而可靠地复制了肩膀的解剖结构。这项研究将确保患者在替代肩关节中保持良好的强度和活动度。
642
[Page extract]
Medical devices and aids
Medical device manufacturers operate in one of the world’s most competitive and highly-regulated industries, where patient safety is critical.
643
Case study
测试金属百叶窗原材料的抗张强度
要求Soprofen Industrie是法国金属卷帘和车库门的领先制造商。他们之所以与Mecmesin接触是因为他们想开发新的力测试方法以改善其原材料和成品的质量控制。 Soprofen有许多不同的测试应用程序,包括确定铝和钢样品的拉伸强度和伸长极限,以及测试其夹具安装件和滑动压接环的强度。结果,他们需要一个灵活的解决方案,使他们能够开发一系列不同的拉伸试验。
645
[Page extract]
ASTM D3032
These test methods detail the standard procedures for testing hookup wire insulations including all components of the insulation system used on single insulated conductors or an assembly of single insulated conductors such as a cable bundle and harness
646
[Page extract]
ASTM F2193-02
These specifications and test methods provide standard specifications that specify material, labeling, and handling requirements for components used in surgical fixation of the spinal skeletal system such as metallic spinal screws, spinal plates, and sp
647
[Page extract]
BS ISO 11040-4
This part of ISO 11040 applies to — tubing-glass barrels (single-chamber design) for injection preparations, and — sterilized subassembled syringes ready for filling.
648
Event
Fundamentals of Torque Testing
If you have ever struggled to open your favorite bottle of water or jam or required help loosening the lug nuts on your car’s wheels, it is likely due to a case of over-torque.
649
[Page extract]
BS EN 12568
Protective footwear, Protective clothing, Toe-caps, Metals, Non-metals, Impact strength, Performance testing, Dimensions, Length, Impact testing, Compression testing, Penetration tests, Corrosion resistance, Corrosion tests, Bend testing, Marking, Test
650
[Page extract]
ASTM D3578
Scope... 1.1 This specification describes certain requirements for natural rubber gloves used in conducting medical examinations and diagnostic and therapeutic procedures. It also covers natural rubber gloves used in handling contaminated medical