Search results
1001
Accessory
Lightweight Vice Grip - Double Action, 250 N, Opening 0-8mm, 10-32 UNF
Mec227
MEC 227 (body only):
A Lightweight Vice Grip providing free adjustment of both jaws, allowing them to be aligned around the central axis to accommodate tensile testing of both symmetrical and asymmetrical specimens.
Rated to 250 N in tension with an…
1002
Accessory
Mounting Plate for CFG+ Compact Force Gauge
432-131
Allows a CFG+ Compact Force Gauge to be mounted onto the crosshead of a test stand. Fixing screws included.
1003
Accessory
standard T-slot fixture table
432-243
This standard fixture table is used for easy configuration and alignment of test fixtures. Fits to a T-slot anvil.
1004
Accessory
Compression Plate, Rubber-Faced, 50 mm, 10-32 UNF
432-220
50mm nickel-plated compression plate featuring a rubber layer, which helps to prevent damage from metal-to-metal contact during a compression test. Fitted with 10-32 UNF female thread. Nickel-plated compression plates are resistant to rusting.
1005
Accessory
Large Single-action Vice Grip, wave-form, 2 kN, QC-20 fitting
432-267-V02
A Large Single-action Vice Grip featuring one fixed jaw and one jaw as freely adjustable to mechanically clamp the specimen in place.
Rated to 2 kN in tension with wave-form jaws of 78mm wide x 28mm high having an opening of 0 - 6.5 mm. Provides…
1006
Accessory
Self-levelling Compression Plate Steel - 156 mm, 50 kN, QC-32 fitting
MecS223g-156
MecS223g - 156mm diameter:
Self-levelling allows exact parallelism to be set between the upper and lower plates - ideal for those applications where it is critical to accurately measure the deformation of a sample.
The MecS223 range of hardened steel,…
1007
Accessory
Lightweight Mini Vice Grip, 5 N, M6
432-281
By virtue of its spring loaded clamping action the Lightweight Mini Vice Grip is ideal for testing ultra low forces.
Weighing only 30 g it holds specimens without the need to tighten jaws by a thread, which may damage low-capacity loadcells or even the…
1008
Accessory
Adapter, 5 kN, 5-16 UNC to M10, M to M
432-333
Male-to-male Adapter
Allows a grip to be connected to a force gauge/loadcell or test stand where thread connections are different.
1009
Accessory
Cone Point - 8 mm diameter, 500 N, 10-32 UNF
432-358
A Cone Point probe of Ø 8mm with angle of 60°.
For compression testing of various components or materials up to 500 N.
Typically used where compressive force needs to be applied at a point or for penetration into a material over a short distance.…
1010
Accessory
Compression Plate, Vented by Holes & Cone, 50 mm, 5-16 UNC
432-348
Vented compression plates are ideal for top-load/crush testing of containers such as PET bottles.
Holes in the plate allow the passage of air to ensure that air inside the bottle is not compressed thereby falsifying the true measurement of the top-load…
1011
Accessory
Cable Cam Grip (small), serrated, 1 kN, 10-32 UNF
432-390
Cable Cam Grip - serrated, small
Designed for holding insulated cables and wire. The sample is secured by the cam, which self-tightens as a load is applied and spreads the load evenly.
Serrated cams are preferred for materials which may be slippy and…
1012
Accessory
Self-levelling Compression Plate Steel - 116 mm, 50 kN, QC-32 fitting
MecS223g-116
MecS223g - 116mm diameter Self-levelling Compression Plate:
Self-levelling allows exact parallelism to be set between the upper and lower plates - ideal for those applications where it is critical to accurately measure the deformation of a sample.
The…
1013
Accessory
Padded Radiused Probe, 500 N, 5-16 UNC
432-414
The Padded Radiused Probe is used with a short extension rod to connect to a digital force gauge to measure tension and compression.
It has a thin layer of rubber and is specially designed for use in manual handling and ergonomic assessment applications…
1014
Accessory
Self-levelling Compression Plate Steel - 56 mm, 25 kN, QC-20 fitting
MecS223k-56
MecS223k - 56mm diameter:
Self-levelling allows exact parallelism to be set between the upper and lower plates.. ideal for those applications where it is critical to accurately measure the deformation of a sample.
The MecS223 range of hardened steel…
1015
Accessory
Coefficient of Friction Fixture (ISO 8295)
432-501
Designed to measure the coefficient of friction (COF) to ISO 8295 between two pieces of material. The COF test determines the kinetic and static resistance of one surface being dragged across another. This friction table can be precisely leveled.
1016
Accessory
Scissor Grip, 5 kN, QC-20 fitting
Mec11-5
MEC11-5 Scissor-action grip (Body only) :
Rated to 5 kN fitted with QC-20 connection.
Spring tension provides enough clamping force to prevent the specimen from slipping when initially inserted. The rated tensile force changes according to the opening…
1017
[Page extract]
Cosmetics & Personal Care Products
Mecmesin solutions for testing in cosmetics and personal care.
Test product formulation for objective texture analysis as well as applicators, dispensers and packaging.
1019
[Page extract]
Bearings, rollers and gears
Rollers and bearings are intrinsic components of assemblies which move products horizontally, vertically, on an incline or decline, overhead, sub-floor, around obstacles and over long distances.
1020
[Page extract]
Transition from Emperor software to VectorPro
Mecmesin's Emperor software based products, including the MultiTest-i/xt, Helixa-i/xt, and Vortex-i/xt, are no longer available to order from 31 December 2023.
1021
[Page extract]
Furniture and soft furnishings
Furniture is manufactured using different kind of wood materials typically from particle board, fiberboard and plywood. Pieces are assembled and joined using glues, adhesive bonds,fixing dowels and fastenings.
1022
[Page extract]
Brushes
Brushes use synthetic or natural filaments to create bristles which are typically clamped to a handle via a ferrule.
1023
[Page extract]
Magnets and solenoids
Solenoids, a type of electromagnet generating a uniform magnetic field when an electric current is passed through it, have applications in many different types of industries.
1024
[Page extract]
Case Studies and Examples
Explore how leading healthcare companies use Mecmesin equipment for syringe testing to ensure compliance with ISO 11040-4 Annex F.
1025
[Page extract]
Gels and hydrocolloids
Gels and hydrocolloids such as agar, gelatin, xanthan and guar gum, etc. are widely used in the food, cosmetics/personal care, and medical/pharmaceutical industries.