Search results
826
Caso de estudio
Luer lock fastening and release torque
Customised engineering example
Luer lock test standards frequently call for measuring torque whilst simultaneously applying a pre-defined axial force.
827
Caso de estudio
Electrical connector insertion and withdrawal forces
Customised engineering example
Push-fit electrical connectors with hole or dimple detents (also known as 'spade terminals') must offer a firm but practical fit.
828
[Page extract]
PSTC 131
SCOPE
1.1 The procedures in this test method describe the measurement of breaking strength, elongation
at break, and energy to break, of pressure sensitive tapes.
829
[Page extract]
BS EN 12697-23
This standard specifies a test method for determining the (splitting) indirect tensile strength of cylindrical specimens of bituminous mixtures.
830
[Page extract]
BS EN 1607
This European Standard specifies the equipment and procedures for determining the tensile strength of a product perpendicular to its faces. It is applicable to thermal insulating products.
831
Caso de estudio
Sistema de calibración de dispositivos de sutura médica.
Requisito Debieron probarse varios dispositivos que 'engarzan' una aguja curva a un hilo médico fino. La fuerza de engarzado se aplicó horizontalmente tirando de una palanca en el dispositivo.
832
Página
You have been subscribed to the Mecmesin newsletter
Thank you
We hope you enjoy the regular updates on our developments in force, materials and torque testing.
833
Caso de estudio
Extracción del accesorio de la jeringa Luer lock
Ejemplo de ingeniería personalizada Nuestro cliente es una empresa biomédica que fabrica soluciones médicas de HA suministradas en jeringas de vidrio con cerraduras Luer de policarbonato de compresión.
834
[Page extract]
BS EN ISO 4624
Describes methods for determining the adhesion by carrying out a pull-off test on a single coating or a multi-coat system of paint, varnish or related product.
835
[Page extract]
ASTM D3165
This test method is useful in that the joint configuration closely simulates the actual joint configuration of many bonded assemblies.
836
[Page extract]
BS EN ISO 10555-5
Catheters, Cannulas, Sterile equipment, Parenteral infusion equipment, Medical instruments, Medical equipment, Disposable, Colour codes, Preferred sizes, Diameter, Syringes, Flow rates, Packaging, Tensile testing, Mechanical testing, Testing conditions,
837
Caso de estudio
Smoke grenade canister integrity
Customised engineering example
A manufacturer of smoke grenades required a means of testing the cap pull-off strength. The particular challenge was to grip the smooth metal cylinder for up to 5 kN of pulling force.
838
[Page extract]
ASTM F88/F88M
ASTM F88 test method covers the measurement of the strength of seals in flexible barrier materials. Seal strength is the tensile strength of the seal at ambient temperature.
839
[Page extract]
ASTM D885/D885M-10a
These [comprehensive] test methods cover the testing of industrial filament yarns made wholly of manufactured organic-base fibers, cords twisted from such yarns, fabrics woven from such cords, and products that are made specifically for use in the manuf
840
Caso de estudio
Tea bag integrity
Customised engineering example
Some of the simplest applications may not seem so obvious when you face them. A string and tab on a tea bag?
841
[Page extract]
BS EN 20594-1
Conical fittings (syringes), Syringes, Injection instruments, Medical instruments, Medical equipment, Tapered, Dimensions, Surgical instruments, Leak tests, Pressure testing, Mechanical testing, Torsion testing
842
[Page extract]
BS EN ISO 80369-20
These standards describes the methods for testing the performance of 6% Luer lock fittings including assembly, leak tightness, stress cracking, and separation force.
844
[Page extract]
BS EN ISO 10618
Carbon fibres, Mechanical properties of materials, Tensile strength, Tensile testing, Plastics, Impregnated materials, Yarn, Modulus of elasticity, Strain, Tensile strain, Loading, Reinforcing materials, Composite materials, Test equipment, Test specime
845
[Page extract]
ASTM C1292
This test method covers the determination of shear strength of continuous fiber-reinforced ceramic composites (CFCCs) at ambient temperature.
846
[Page extract]
*corp Mastercard CQM: ID-1
Mastercard CQM requirement covers Peel Strength Test (TM-412 #8120#) and Advanced Peel Strength Test (TN-424 #8240#). Methods are based around ISO 10373-1 to determine the peel strength between 2 layers of an ID or security card.
847
[Page extract]
ISO 2409
Describes a test method for assessing the resistance of paint coatings to separation from substrates when a right-angle lattice pattern is cut into the coating, penetrating through to the substrate.
848
[Page extract]
ASTM C1368
This test method covers the determination of slow crack growth (SCG) parameters of advanced ceramics by using constant stress-rate rectangular beam flexural testing, or ring-on-ring biaxial disk flexural testing, or direct tensile strength, in which str
849
[Page extract]
BS ISO 6133
BS ISO 6133 specifies five methods of calculating, after testing, the tear strength and the adhesion strength of vulcanized rubber or fabrics coated with or adhered to rubber or plastics.
850
[Page extract]
ASTM D6742 / D6742M
ASTM D6742 is the standard test method for tensile and compression testing of filled-hole polymer matrix composite laminates. It provides instructions for modifying open-hole tension and compression test methods to determine filled-hole tensile and com